cms_SC: 5616

In collaboration with The Seattle Times, Big Local News is providing full-text nursing home deficiencies from Centers for Medicare & Medicaid Services (CMS). These files contain the full narrative details of each nursing home deficiency cited regulators. The files include deficiencies from Standard Surveys (routine inspections) and from Complaint Surveys. Complete data begins January 2011 (although some earlier inspections do show up). Individual states are provides as CSV files. A very large (4.5GB) national file is also provided as a zipped archive. New data will be updated on a monthly basis. For additional documentation, please see the README.

This data as json, copyable

rowid facility_name facility_id address city state zip inspection_date deficiency_tag scope_severity complaint standard eventid inspection_text filedate
5616 WOODRUFF MANOR 425179 1114 EAST GEORGIA ROAD WOODRUFF SC 29388 2015-06-04 490 L 0 1 02VR11 **NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** Based on observations, record reviews and interviews the Administrator failed to train and/or provide a job description for the facility Maintenance Director which contributed to immediate jeopardy and/or substandard quality of care. The findings include: Cross refer CFR 483.25 F-323 Free of Accident Hazards On 6/3/15 at approximately 10:00 AM a review of the Maintenance Director personnel file revealed the Date of Hire as Floor Tech: 8/16/13 and Promoted to Maintenance Director/Housekeeping Supervisor: 9/26/14. Further review failed to show a job description or evidence of training for the Maintenance Director. The Administrator stated that s/he was unable to locate a Maintenance Director job description or a record of training for the Maintenance Director. The Administrator was notified at approximately 5:00PM on 6/2/2015 of the Immediate Jeopardy and/or Substandard Quality of Care related to excessive hot water temperatures in resident rooms. An Allegation of Compliance (A[NAME]) was submitted by the facility on 6/3/15 at approximately 8:45 AM. The actions listed in the A[NAME] included the following: I. Corrective Action taken to remove the Immediate Jeopardy: On 6/2/2015 at approximately 5:00pm (sic), the survey team notified the facility that an Immediate Jeopardy situation was present in regards to Hot Water Temperatures on the 200 Unit. The survey team stated that resident room temperatures on the 200 Unit were in excess of 120 degrees (highest temperature reported was 124 degrees). It was stated by the survey team leader that excessive temperatures were limited to the 200 Unit and that the other Unit's temperatures (100 Unit) were in compliance. The Administrator informed the nursing staff on the 200 Unit to cease using hot water on 6/2/15 at approximately 5:20pm (sic) until the situation was resolved. On 6/2/15 The DON, in coordination with the Licensed Nursing Staff completed 100% body audits on all residents on both units to ensure that there was no evidence of any resident injury or bums due to hot water. The findings of the body audits concluded that there had been no injuries [MEDICAL CONDITION] residents. The Maintenance Director contacted the facility's contracted plumber and they dispatched a plumber to the facility immediately. The plumber, along with the Maintenance Director and Regional Director of Operations visibly inspected the two hot-water heaters that control resident room temperatures on the 200 Unit. The two hot water heaters each have their own thermostats but are then connected by an adjustable mixing valve. The plumber adjusted the left thermostat to the lowest allowable setting. In addition, the mixing valve was adjusted approximately a 1/4 inch colder temperature to ensure compliance. At 6:15, the plumber, Maintenance Director, and Regional Director of Operations conducted an initial test of a resident room where excessive temperatures had been noted by the survey team. At that time, the temperature at the resident sink was noted to be 117 degrees, indicating that the adjustments made to the thermostat had successfully removed the immediate jeopardy to the residents. At 6:30pm (sic) the plumber signed a Teachable Moment form, indicating that he had educated the Maintenance Director on adjusting the thermostats and mixing valves to achieve the desired temperatures, as well as proper calibration of thermometers. At the plumber's recommendation, new Digital Thermometers were purchased by the facility Administrator on 6/2/2015. At IOpm (sic), The Maintenance Director and Regional Director of Operations checked 100% (12 on each of 2 Units) of resident bathroom sinks and shower rooms on 6/2/2015. All temperatures were within regulatory limits (100 - 120 degrees). The facility has no recorded grievances by residents that the room water temperatures were too hot. The facility has had no incidents of residents being burned or scalded by hot water. 2. Measures put into place or systemic changes made to ensure that the immediate jeopardy will not recur: The Administrator and Regional Director of Operations inserviced the Maintenance Director on 6/2/2015 regarding the requirement to check resident room temperatures in accordance with facility policy. A log to record temperatures was provided and will be utilized to ensure ongoing compliance. The water temperature log will be completed daily for two weeks to ensure stability of temperature settings, and weekly thereafter. Any temperature readings in excess of 120 degrees will be corrected immediately and reported to the facility Administrator. The Staff Development Coordinator began inservicing all nursing staff on 6/2/2015 on the facility's Safety of Water Temperatures policy. No nursing staff will be allowed to work until having received this inservice. This inservice includes: o Any time water feels excessively hot to the touch (i.e., hot enough to be painful or cause reddening of the skin after removal of the hand from the water), staff will report this finding to their immediate supervisor. o Risk factors for scalding/burns that are more common in the elderly, such as: Decreased skin thickness; Decreased skin sensitivity; Peripheral [MEDICAL CONDITION]; Reduced reaction time; Decreased cognition; Decreased mobility, and Decreased communication. o Other factors that influence temperature tolerance (length Of exposure, amount of skin exposed, and the resident's current condition). o Signs and symptoms [MEDICAL CONDITION](first, second, and third degree) o If a resident is scalded or burned, nursing staff shall follow pertinent first aid and physician notification protocols and report the injury to his or her direct supervisor. As a precaution, the hot water heaters that control resident room water temperatures on the 100 Unit were reviewed by the plumber, Maintenance Director, and Regional Director of Operations. The findings of the review indicated the left hot water heater was set on 120 degrees, and the right was set on 110. The water from the two hot-water heaters is combined prior to entering the facility. The thermostat of the left hot water heater was reduced to 115 degrees. There has been no reported temperatures on the 100 Unit in excess of 120 degrees. All new nursing staff will be oriented regarding the Safety of Water Temperatures policy during orientation. Any new Maintenance personnel will also be oriented on this policy, and the log for tracking hot-water temperatures. Results of hot-water temperature monitoring will be brought to the Quality Assurance Committee monthly to ensure ongoing compliance. However, any noted temperatures above the allowable range of 100-120 degrees will be corrected immediately and reported to the facility Administrator. Observations, review of policy, education and signature sheets on 6/3/15 revealed the Allegation of Compliance submitted by the facility on 6/3/15 had been implemented by the facility and was in practice removing the immediacy of the deficient practice. The Administrator was informed of this on 6/3/15 at 5:25 PM. The citations at F-323, F-490, and F-520 remained at a lower scope and severity of F. 2018-11-01